AK Series Generator Ganging
Specification Sheet
Amerec steam generators may be ganged together to supply steam to rooms larger than what a single 14kW unit can accommodate. When ganging generators, only one has a control and temperature sensor connected. Secondary units mimic the primary unit, making the system operation as simple as controlling a single generator.
- Each steamer requires at least one ComfortFlo steam head (we recommend at least 2 heads for 14kW units) and more steam heads per unit may be desirable to reduce steam noise.
- Each steamer will need its own automatic drain valve kit
- Each steamer will need its own drip pan
Note: You may gang an AK steamer only with other AKs.
Required Part:
- Item #5304-031 AX Ganging cable.
One required for each secondary steamer.
For further information, refer to Amerec doc:
4211-1551 AK Installation Instructions
Ganged System Ratings
| Max cu ft | Max cu m | Steamer Models Used | |||||
|---|---|---|---|---|---|---|---|
| System kW | kW | Qty | Model | Qty | Model | ||
| AK/AX 18 | 18 | 700 | 19.8 | 2 | AK/AX 9 | ||
| AK/AX 22 | 22 | 900 | 25.5 | 2 | AK/AX 11 | ||
| AK/AX 28 | 28 | 1100 | 31.2 | 2 | AK/AX 14 | ||
| AK/AX 30 | 31 | 1300 | 36.8 | 1 | AK/AX 9 | 2 | AK/AX 11 |
| AK/AX 36 | 36 | 1500 | 42.5 | 2 | AK/AX 11 | 1 | AK/AX 14 |
| AK/AX 42 | 42 | 1800 | 51.0 | 3 | AK/AX 14 | ||